Commercial building plant room with plumbing and pipework installation
Plumbing & Fire Protection Systems

Plumbing & Fire Protection Systems

Reliable building infrastructure engineered for performance, safety and long-term operation.

Complete Building Services Infrastructure

Energon Solutions designs and installs plumbing and fire protection systems for residential, commercial, healthcare, education and public buildings across Cyprus. Our certified engineers deliver compliant, high-quality installations that meet current Cypriot and European standards.

From domestic water supply and drainage to fully engineered automatic sprinkler systems and fire pump installations, we manage every stage — design, procurement, installation, testing and commissioning — under a single contract.

Plumbing Systems
Cold, hot water, drainage & storage
Fire Protection
Sprinklers, pumps & hose reels
Pressure Testing
Hydraulic test to 1.5× working pressure
Full Documentation
As-builts, O&M manuals & certificates

Plumbing Systems

Water Supply, Distribution & Drainage

Domestic Cold & Hot Water Systems

Domestic Cold & Hot Water Systems

Reliable supply to every point of use

We design and install cold and hot water distribution networks for all building types, from single-family homes to large multi-storey developments. Systems are sized for peak demand, insulated to prevent heat loss and configured to minimise dead-leg lengths for water quality compliance.

  • Cold water distribution from mains or storage
  • Hot water circulation with trace heating where required
  • Legionella risk management design
  • Insulation and labelling to specification
Pressure Boosting Installations

Pressure Boosting Installations

Consistent pressure across all floors and zones

Where mains pressure is insufficient for multi-storey or high-demand applications, we design and install packaged booster pump sets with duty/standby configuration, pressure vessels and intelligent controls. Systems are commissioned to deliver stable pressure at all draw-off points regardless of demand variation.

  • Duty/standby pump set configurations
  • Variable-speed drive (VSD) pumps for energy efficiency
  • Pressure vessel sizing and installation
  • BMS integration and remote monitoring
Central Hot Water Production

Central Hot Water Production

Efficient, reliable hot water for large buildings

Central hot water systems for hotels, student accommodation, healthcare facilities and apartment blocks require careful design to balance capacity, efficiency and hygiene. We specify and install calorifiers, heat exchangers, solar thermal collectors and heat pump water heaters, integrated with building controls for optimised operation.

  • Calorifier and heat exchanger selection and installation
  • Solar thermal and heat pump integration
  • Temperature control and pasteurisation scheduling
  • Expansion vessel and safety valve provision
Drainage & Sewage Systems

Drainage & Sewage Systems

Above and below ground drainage to specification

Our drainage installations cover above-ground soil and waste systems, below-ground foul and surface water drainage, and pumped sewage ejector systems where gravity drainage is not possible. All installations comply with applicable Cypriot building regulations and EN standards.

  • Above-ground soil, waste and vent pipework
  • Below-ground foul and surface water drainage
  • Pumped sewage ejector and macerator systems
  • Grease interceptors and petrol interceptors
Water Storage & Distribution

Water Storage & Distribution

Secure water reserves for continuity of supply

Break tanks, cold water storage cisterns and pressurised distribution systems ensure continuity of supply in buildings where direct mains connection is impractical or where fire reserve storage is required. We design storage systems to meet both domestic demand and fire fighting reserve requirements.

  • GRP and stainless steel storage tank supply and installation
  • Break tank and booster set combinations
  • Fire reserve storage integrated with domestic supply
  • Tank cleaning, inspection and maintenance

Fire Protection

Life Safety Fire Protection Systems

Automatic Sprinkler Systems

Automatic Sprinkler Systems

The most effective passive fire suppression available

Automatic sprinkler systems are the single most effective measure for controlling fire spread in buildings. Energon Solutions designs and installs wet pipe, dry pipe and pre-action sprinkler systems to EN 12845 and NFPA 13 standards, covering residential, commercial, industrial and public building applications.

  • Wet pipe, dry pipe and pre-action systems
  • Design to EN 12845 and NFPA 13
  • Concealed and exposed head configurations
  • Integration with fire alarm and BMS
Fire Pump Installations

Fire Pump Installations

Reliable water supply for fire suppression systems

Fire pump sets provide the pressure and flow required by sprinkler and hydrant systems when mains supply is insufficient. We design and install electric and diesel-driven fire pump sets with jockey pumps, test facilities and automatic start controls, fully compliant with EN 12845 and local authority requirements.

  • Electric and diesel fire pump configurations
  • Jockey pump and automatic start controls
  • Weekly and annual test facilities
  • Compliance with EN 12845 and authority requirements
Fire Hose Reels

Fire Hose Reels

First-response firefighting for building occupants

Fire hose reels provide building occupants and first responders with an immediate water supply for initial fire attack. We supply and install swinging-arm and recessed hose reel cabinets, sized and positioned to provide coverage to all areas of the building in accordance with BS EN 671 and local fire authority guidance.

  • Swinging-arm and recessed cabinet installations
  • Coverage design to BS EN 671
  • Dedicated hose reel supply pipework
  • Annual inspection and flow testing
Fire Protection Pipework

Fire Protection Pipework

Engineered distribution networks for all fire systems

The reliability of any fire protection system depends on the quality of its pipework distribution network. We fabricate and install steel, CPVC and stainless steel fire protection pipework systems, including hangers, supports, flexible connections and all associated valves and fittings, to the highest installation standards.

  • Steel, CPVC and stainless steel pipework
  • Fabrication and site installation
  • Hangers, supports and seismic bracing
  • Zone control valves and monitoring switches
Testing & Preventive Maintenance

Testing & Preventive Maintenance

Keep life safety systems ready when they are needed

Fire protection systems must be maintained in full operational readiness at all times. Energon Solutions provides scheduled inspection, testing and maintenance programmes for sprinkler systems, fire pumps and hose reels, including weekly pump tests, annual flow tests and full system inspections with written reports.

  • Weekly, monthly and annual inspection schedules
  • Pump performance and flow testing
  • Sprinkler head replacement and system flushing
  • Written inspection reports and compliance records

Quality Assurance

Testing, Commissioning & Documentation

Every Energon Solutions installation is subject to a rigorous quality assurance process before handover. Our approach ensures that systems perform to design intent, comply with applicable standards and are fully documented for the building owner and future maintenance teams.

Pressure Testing

All pipework systems undergo hydraulic pressure testing to 1.5× working pressure, witnessed and recorded before concealment. Test certificates are issued for every system.

System Commissioning

Plumbing and fire protection systems are commissioned to design flow rates and pressures, with all controls, alarms and interlocks verified in the presence of the client or their representative.

Technical Documentation

We provide full as-built drawings, operation and maintenance manuals, test certificates, equipment data sheets and warranties for every installation — essential for building compliance and future maintenance.

Applicable Standards

Our installations comply with EN 806, EN 12845, BS EN 671, NFPA 13, local Cypriot building regulations and project-specific specifications. We work closely with consultants and authorities to ensure full compliance.

Engineer conducting pressure testing and commissioning of pipework systems

Every installation pressure-tested, commissioned and fully documented before handover.

Featured Projects

Delivered for Cyprus's Leading Institutions

Frederick University Student Halls

Nicosia, Cyprus

Complete plumbing and fire protection installation for a large student residential development, including domestic cold and hot water systems, central hot water production, drainage, automatic sprinkler system and fire pump installation serving multiple residential blocks.

Domestic PlumbingSprinkler SystemFire PumpEducation

Municipal Care Home Larnaca

Larnaca, Cyprus

Full mechanical services installation for a municipal care home, encompassing domestic water systems with enhanced Legionella controls, central hot water production, drainage and a complete fire protection package including sprinklers, hose reels and fire pump set.

Healthcare PlumbingFire ProtectionLegionella ControlsPublic Sector

Ready to Discuss Your Project?

Our engineers are ready to review your requirements and provide expert guidance on the right plumbing and fire protection solution for your building.